Mounting Assembly — Select Valve Type & Material
(Includes valve, close nipple & weld coupling)
Sensor (Valve Size NPT)
10 (1-1/4) 15 (2”) Type & Material
Code
B5B B8B Ball, Brz
B5C B8C Ball, CS
B5S B8S Ball, SS
G5C G8C Gate, CS
G5S G8S Gate, SS
Code Options
SS Wetted Components
WPS
(Furnished with SS weld coupling, close & access nipple).
Must be ordered with SS access valve.
V250 8”sch40 10 H R C2NC B5C Typical Model Number
Ordering Information
Instrument Valves (Opt.) Manifolds (Optional)
Remote Mount Direct Mount
Needle Gate 3-Valve 5-Valve
C2NC (CS) C2GC (CS) F3SC (CS) F3HC (CS) F5SC (CS) F5HC (CS)
C2NS (SS) C2GS (SS) F3SS (SS) F3HS (SS) F5SS (SS) F5HS (SS)
1/2” NPT Soft Seat Hard Seat Soft Seat Hard Seat1/2” NPT
Model Hot Tap • Threaded Pipe Connections and Components
V250 Hand Insert/Retract, Low Pressure
Pipe Size and Schedule or Exact ID and Wall Thickness
Code Sensor Pipe Size Range
10 6” to 42” (150mm to 1050mm)
15 12” to 60” (300mm to 1500mm)
Code Pipe Orientation
H Horizontal
V Vertical
Instrument Connections
(Select Remote or Direct Mount)
(Transmitter sold separately)
Remote Mount Transmitter Direct Mount Transmitter
(1/2” NPT) (Flanged 450°F/232°C Max.)†
Parallel Regular RTD
*
Valve Transmount Mass Transmount
*
Manifold
PR D T F G E M
Explsn. Proof
Remote
RTD
Integral
RTD
Integral
Integral
Optional
*
For high pressure (>500psig) or high temperature (>500°F), remote mount RTD in a thermowell is preferred.
† Assuming adequate heat dissipation for transmitter.